Skip to content
Wattleigh

How to install a plug-in solar kit, step by step

The safe, legal order: checks first, the kit's own mount, register before use, then straight into a wall socket. With stop points at each step.

ResearchedRules checked See the rules

By Wattleigh Editorial Team · Last updated

How we're paid: We don't earn from any retailer on this page yet. If that changes, this line will say so. How we make money

Quick answer

How to install plug-in solar, in short: if your kit passes the four buying checks and your consumer unit is suitable, fix the panels with the kit’s own mount, connect the kit’s own cables exactly as its instructions say, fit the consumer-unit label, register the kit, then plug its lead straight into a wall socket on a socket circuit. Stop and get a qualified electrician first if you have old rewireable fuses, a Type AC RCD (Electrical Safety First’s advice) or would need a new outdoor socket. With more than 960 W of panels, the spec says you should consider having your wiring checked first (DESNZ product spec v2; Electrical Safety First).

Based on: the DESNZ product spec v2 and Electrical Safety First, checked 2 November 2026

Illustration: a plug-in solar kit's moulded UK plug pushed straight into a switched wall socket, its lead running down the wall and along the skirting towards a window, with a freestanding panel on its stand in the garden outside. No extension lead or adaptor.

Illustration: Wattleigh

Rules checked: . Plug-in solar is legal in England, Wales and Scotland, not yet in Northern Ireland. One compliant kit per household, up to 800 W into your wiring. Full rules: is plug-in solar legal in the UK?

How to install a plug-in solar kit in 10 steps, with stop points Diagram of the ten steps to install a plug-in solar kit, in order. Step 1: Check your consumer unit and RCD, with a stop point. Step 2: Choose the socket, with a stop point. Step 3: Choose the spot, with a stop point. Step 4: Put the mount together, with a stop point. Step 5: Fit the panels and connect them to the inverter. Step 6: Route the lead. Step 7: Fit the consumer-unit label. Step 8: Register before you switch on. Step 9: Plug straight into the wall socket, marked "never between the kit and the socket". Step 10: First checks. The pictures show a closed consumer unit from the front, a UK wall socket, the sun and shade, the maker's stand, a panel connected to the inverter, the lead running along the floor to a socket, the label next to the consumer unit, a phone with a tick, the moulded plug in the wall socket, and the RCD test button with the sun out. Follow your kit's instructions for the method. Install in 10 steps Follow your kit's instructions for themethod.1Check yourconsumer unitand RCDStop point2Choose thesocketStop point3Choose the spotStop point4Put the mounttogetherStop point5Fit the panelsand connect themto the inverter6Route the lead7Fit theconsumer-unitlabel8Register beforeyou switch on9Plug straightinto the wallsocketNever betweenthe kit andthe socket10TFirst checksOriginal diagram by Wattleigh · wattleigh.com
Original diagram by Wattleigh. The order follows DESNZ product spec v2 (8.1–8.3.5). Follow your kit's instructions for the method.

Before you start: five things to settle

  1. The kit passes the four checks. It states it meets the government’s product spec, shows as Compliant on the ENA Type Test Register (the maker and the model or device reference must both match), has a moulded 13 A plug fused at 5 A or less, and comes with its own mount and consumer-unit label (DESNZ product spec v2; ENA Type Test Register). How: check a kit is compliant.
  2. Permission, if you rent or own a flat. The new law gives you no right to install. Check your tenancy or lease and ask your landlord, freeholder or managing agent before you buy. Get the answer in writing, including who pays for what (DESNZ product spec v2). See plug-in solar for renters and plug-in solar in flats and leasehold homes.
  3. Planning. In England, plug-in solar falls under the permitted development rules for home solar, with limits; Wales and Scotland have made no plug-in-specific change. If your home is listed, in a conservation area or a World Heritage Site, or you’re unsure, ask your council before buying (SI 2026/896; Energy Saving Trust checklist).
  4. Your insurance. The product spec makes checking your insurance your responsibility, and insurers differ. Before you install, ask your home insurer (and your building’s insurer, in a flat) whether you need to tell them (DESNZ product spec v2).
  5. Your consumer unit. The first stop point (Step 1). Check it before you buy if you can.

Already have rooftop solar? A plug-in kit can still be allowed, but only if your total generation stays within the G98 limit (16 A per phase). Check with your installer or network operator first (Ofgem G98 decision).

What’s in the box, and what you’ll need

Check the box against this list:

What should be there What to check If missing or wrong
Panel(s) Up to four panels, up to 2,000 W in total Contact the seller
Inverter A small box, usually behind the panel Contact the seller
Plug lead A moulded UK 13 A plug (square pins) with a fuse of 5 A or less. Not a European round-pin plug or a rewireable plug Don’t use the kit. Never fit a different plug or use a travel adaptor
Mounting system The maker’s own stand, bracket or frame See below
Consumer-unit label A durable label to stick at or near your consumer unit Ask the seller for one
Instructions In English, covering circuits, RCD testing, permissions, planning, insurance and registration (link or QR code) Ask the seller before installing

Source for every row: DESNZ product spec v2 (sections 1, 4.1, 5.5.1, 6.2.3.2, 8.1–8.3). The last column is our advice.

No mount in the box? The spec describes the mount as part of the kit, and we only recommend kits with the manufacturer’s own mounting system. Look for the same maker’s “with mounting system” version (DESNZ product spec v2).

Read the instructions all the way through first. If they show a European plug, give a deadline for registering after you switch on, or say the kit works with a battery, stop and ask the seller: those conflict with the current rules (DESNZ product spec v2).

Tools and extras. Use only what your kit’s instructions list; it varies by kit.

What's in the box: what a compliant plug-in solar kit should include Illustrated list of what a compliant plug-in solar kit should include. Panel(s): Up to four panels, up to 2,000 W in total. Inverter: A small box, usually behind the panel. Plug lead: A moulded UK 13 A plug (square pins) with a fuse of 5 A or less. Not a European round-pin plug or a rewireable plug. Mounting system: The maker's own stand, bracket or frame. Consumer-unit label: A durable label to stick at or near your consumer unit. Instructions: In English, covering circuits, RCD testing, permissions, planning, insurance and registration (link or QR code). Plug lead: Never fit a different plug or use a travel adaptor. No mount in the box? Look for the same maker's "with mounting system" version. What's in the box Check the box against this list.Panel(s)Up to four panels, up to 2,000 W intotalInverterA small box, usually behind thepanelPlug leadA moulded UK 13 A plug (squarepins) with a fuse of 5 A or less.Not a European round-pin plug or arewireable plugNever fit a different plugor use a travel adaptorMounting systemThe maker's own stand, bracket orframeConsumer-unit labelA durable label to stick at or nearyour consumer unitInstructionsIn English, covering circuits, RCDtesting, permissions, planning,insurance and registration (link orQR code)No mount in the box? Look for the samemaker's "with mounting system" version.Original diagram by Wattleigh · wattleigh.com
Original illustration by Wattleigh: what a compliant kit should include. Source: DESNZ product spec v2.

Step 1: Check your consumer unit and RCD

Your consumer unit (fuse box) is usually near your electricity meter. Look at the front only.

  • The official spec asks for modern residual current protection, such as RCBOs on each circuit. Set-ups with ordinary breakers (MCBs) behind a shared RCD “may also be acceptable”, but the government is still testing this (DESNZ product spec v2).
  • With older-style fuses, the Energy Saving Trust’s checklist (made with DESNZ) says don’t install plug-in solar panels (Energy Saving Trust checklist).
  • Electrical Safety First recommends at least a Type A bidirectional RCD on the circuit you’ll use, and says homes with older Type AC RCDs shouldn’t use plug-in solar until that’s upgraded. The RCD type is usually printed on the device in your consumer unit. If you can’t tell, ask a registered electrician. This is the charity’s advice, not a legal requirement (Electrical Safety First).
  • If your kit has more than 960 W of panels, the official spec says you should consider having a qualified electrician check your wiring first (DESNZ product spec v2).

Glossary: consumer unit, RCD.

Step 2: Choose the socket

  • A socket circuit only. Plug the kit into an ordinary wall socket on a socket circuit, not a lighting circuit or a spur to a cooker or boiler (DESNZ product spec v2). See socket circuit.
  • Know which circuit it’s on. Your kit’s instructions must explain how to identify circuits. The spec’s method is to switch a breaker off and see which sockets lose power: “Sockets that turn off together are on the same circuit.” Our paraphrase: check one breaker at a time, using the switches on the front only. The spec also warns: “Care should be taken when operating the consumer unit/fuse box. Switching off a circuit breaker may interrupt the supply to appliances and equipment.” If the breakers aren’t labelled, or you’re unsure about your consumer unit, ask a registered electrician (DESNZ product spec v2).
  • A sound socket. The kit must not be connected to “damaged, degraded or non-compliant socket outlets”. If a socket is cracked, scorched, loose or feels warm, don’t use it. If in doubt, get a qualified electrician to inspect it (DESNZ product spec v2).
  • Outdoor sockets. An existing weatherproof outdoor socket on a suitable circuit can be used. The spec’s minimum for outdoor plugs and sockets is IP55. The Energy Saving Trust advises an outdoor socket rated at least IP65, fitted by a qualified electrician (DESNZ product spec v2; Energy Saving Trust checklist).

Step 3: Choose the spot

  • Sun and shade. Roughly south with little shade makes the most; shade cuts output, most of all in winter. Compare spots in the plug-in solar calculator.
  • Only where your kit’s maker allows. The instructions must list the permitted mounting types and locations, with any height, wind or snow limits (DESNZ product spec v2).
  • Balcony? See balcony solar panels. Garden or flat roof? Use the kit’s own stand and any ballast the maker specifies.
  • England, houses: fixings on a wall or balcony may stick out no more than 0.4 m (0.2 m next to a road); flats have tighter limits (SI 2026/896).

Step 4: Put the mount together

  • Use the maker’s mount and follow its assembly steps exactly. The spec requires the instructions to cover fastening or ballast for wind and snow (DESNZ product spec v2).
  • No improvised fixings. “Mounting arrangements relying solely on cable ties, rope, string, adhesive tape, bungee cords, straps shall not be permitted.” (DESNZ product spec v2)
  • Reversible and non-permanent. “Any attachment method shall be reversible and non-permanent.” The Energy Saving Trust adds that work affecting weatherproofing or fire safety may count as building work (DESNZ product spec v2; Energy Saving Trust checklist). Our advice: in a flat, don’t drill into the outside walls.
  • Don’t modify anything. The product must not be modified or installed in a way the maker hasn’t specified (DESNZ product spec v2).

Stop point: if the mount doesn’t suit your railing, wall or ground, or a part is missing, stop. Don’t improvise with straps, ties or your own brackets.

Step 5: Fit the panels and connect them to the inverter

  • Keep the plug out of the socket while you do this (our advice: nothing connected to the mains while you assemble).
  • Connect only as instructed, with the kit’s own cables and connectors. Never add Y-connectors (the spec bans them) or panels that didn’t come with the kit: the spec says to use only connection cables the maker specifies or approves, and the product “shall not be modified or installed in a manner not specified by the manufacturer” (DESNZ product spec v2).
  • Never pull panel cables apart while the kit is running. The spec says “DC connectors shall not be disconnected under load and … the AC supply shall be turned off before disconnecting DC connections”. In practice, our reading: unplug the kit from the wall before touching the panel connections (DESNZ product spec v2).

Step 6: Route the lead

  • Route the cable from outside to inside exactly as the kit’s instructions say; they must cover “pull relief, bending radii, no installation in the ground or wet areas” (DESNZ product spec v2).
  • Make sure it can’t be tripped over, pinched in a door or window, trodden on or damaged. London Fire Brigade warns that damaged wiring can overheat or short circuit (London Fire Brigade).
  • If the instructions don’t cover your situation, ask a qualified electrician rather than improvising.

Step 7: Fit the consumer-unit label

Stick the label that came with the kit at or near your consumer unit, so anyone working on your electrics knows a plug-in solar device is there. If the consumer unit is replaced, label the new one too (DESNZ product spec v2). It goes on the outside: there’s no need to open anything.

Step 8: Register before you switch on

Register your kit before you start using it: install it, register it, then switch it on. The official guidance says registering is a legal requirement, and it takes a few minutes (Energy Saving Trust; Electricity North West).

Register at the UK Plug-in Solar Registration website (myplugin.solar). Have your name, postcode, and your kit’s make and model ready. Save or screenshot the on-screen confirmation, because you won’t get an email (Energy Saving Trust checklist). Full guide: how to register your plug-in solar kit.

Step 9: Plug straight into the wall socket

Push the kit’s own moulded plug straight into the socket you chose, and switch it on.

Step 10: First checks

  • Is it working? Every compliant inverter must show its status and any faults, on the device or through an app (DESNZ product spec v2). Compare the first month with our monthly generation figures; expect little on grey winter days.
  • Test the RCD while the panels are generating. The spec says to press the test button on your RCD or RCBO now and then “when the plug-in solar unit is producing power”. The Energy Saving Trust says every six months. If it doesn’t trip, unplug the kit and speak to a qualified electrician (DESNZ product spec v2; Energy Saving Trust checklist).
  • Look and listen in the first week. London Fire Brigade advises stopping use straight away if you notice a burning smell, overheating, buzzing, visible damage or repeated tripping. If you smell burning, call 999. In a fire, don’t touch the system, get to safety, call 999 and tell the fire service you have solar panels (London Fire Brigade).
  • Keep an eye on it. Your kit’s instructions must give inspection intervals, including visual checks of fixings, cables and connectors (DESNZ product spec v2). Our own advice (not in the spec): check the fixings and lead after storms or strong winds.

When to stop and call an electrician

With more than 960 W of panels, the official spec says you should consider having a qualified electrician check your wiring first.

You’re allowed to install a compliant kit yourself. An electrician is only required where the instructions say so (for example, for circuit changes or older fuse boxes) (Ofgem G98 decision). Installing it yourself means the mount, the kit’s own connections and an existing socket, never wiring work. Electrical Safety First recommends a check by a registered electrician before you buy, particularly in older homes (Electrical Safety First).

Not for you yet if you live in Northern Ireland, want to add a battery, or your only spot is a timber balcony or cladding. More: who should not install a kit yet.

Taking it down or moving it

  1. Unplug the kit from the wall first, before you touch any panel connections. Our advice: the spec says to turn the AC supply off before disconnecting the panel (DC) connectors, and unplugging does that (DESNZ product spec v2).
  2. Take the panels and mount down following your kit’s instructions.
  3. Tell the network operator if you permanently remove the kit, including when you move home. Check the registration site for how (Ofgem G98 decision).
  4. At a new home, our advice: register it again at the new address before using it, and check the home doesn’t already have a plug-in kit (one per household).
  5. End of life: follow your kit’s instructions for disposal. Electrical waste (WEEE) rules apply (DESNZ product spec v2).

Printable checklist

Print the checklist (A4)

Before you start

  • Kit: states IPS compliance · ENA register says Compliant (maker and model/device reference match) · moulded 13 A plug, fuse 5 A or less · own mount and consumer-unit label
  • Permission in writing (renters, flats)
  • Planning checked (council if listed, conservation area or unsure)
  • Insurance checked with your insurer
  • Instructions read end to end (no European plug, no battery, no different deadline)

Install

  1. Consumer unit, front only: RCBOs, or MCBs + RCD (check). Stop if old fuses, Type AC or unsure
  2. Socket: socket circuit, sound, reachable without an extension. Stop if you’d need a new socket
  3. Spot: maker-approved; not timber, cladding, an escape route or a party wall. Stop if it is
  4. Mount: maker’s parts and ballast only, reversible. Stop if it doesn’t fit
  5. Panels to inverter: kit’s own cables, plug out of the socket
  6. Lead routed as instructed, not pinched or trodden on
  7. Label at or near the consumer unit
  8. Registered at myplugin.solar, confirmation saved
  9. Straight into the wall socket. Never an extension lead, multi-plug adaptor, RCD adaptor, travel adaptor or battery. Our reading, not an official rule: no smart plug, timer or plug-in energy monitor in between either
  10. Status or app shows it working · RCD test while generating · watch for smells, heat, buzzing, tripping

Electrician first if: old fuses · Type AC or unknown RCD · damaged socket or unknown circuit · new socket or circuit change · RCD won’t trip

Consider an electrician’s check: over 960 W of panels

Next step

  1. Register your kit before you switch on.
  2. Estimate what it should make: the calculator.
  3. Everything else: the complete guide.

Safety wording checked in-house by the Wattleigh team against our rules sheet, Electrical Safety First and Energy Saving Trust guidance; not reviewed by an external electrician. Rule changes: rules log. How we research.

Common questions

Can I install plug-in solar panels myself?
Yes, if it's a compliant kit and no stop point above applies.
Can I use a smart plug to see what it makes?
No, in our reading. Plug the kit into nothing other than a wall socket, and use the kit's own display or app instead.

Keep reading

Everything in Installation and safety

Who wrote this

Wattleigh Editorial Team

The Wattleigh Editorial Team researches and writes every guide on this site. We work from official sources (legislation.gov.uk, DESNZ, Ofgem, the Energy Networks Association, Electrical Safety First) and show the date we last checked the rules on each page. Our guides are researched, not hands-on tested.

How we research and check the rules