Skip to content
Wattleigh

How much electricity does a plug-in solar kit generate in the UK?

Annual and monthly kWh for an 800 W plug-in solar kit in 8 UK cities, by direction and angle. Open EU JRC PVGIS data, assumptions shown.

ResearchedRules checked See the rules

By Wattleigh Editorial Team · Last updated

How we're paid: We don't earn from any retailer on this page yet. If that changes, this line will say so. How we make money

Quick answer

How much electricity does plug-in solar generate? The short answer: with 800 W of panels and no shade, an 800 W plug-in kit in Great Britain makes roughly 680–900 kWh a year when the panels face south and are tilted at 35°. Hung vertically on an east- or west-facing railing, it makes roughly 340–440 kWh a year.

Based on: EU JRC PVGIS v5.3 data (retrieved 10 October 2026) and the DESNZ impact assessment

Chimneys and roofs of terraced houses in Cheltenham in low winter sun, with bare trees behind.

Photo: Richard Bell / Unsplash

Data: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, retrieved 10 October 2026. We have not tested kits ourselves. These figures come from modelling, not measurement.

New to plug-in solar? Start with the complete guide.

Output is lower in Scotland than in the south of England, and only a small share of it comes in December. The government’s own example uses 690 kWh a year for a 30° south-facing kit and 378 kWh a year for a vertical east/west kit (DESNZ impact assessment, Table 7). Our figures are Wattleigh modelling with EU JRC PVGIS data (dataset; method). Your real result will usually be lower if anything shades the panels.

The short answer in one table

Average yearly output for a kit with 800 Wp of panels, no shading, before any 800 W inverter clipping (Wattleigh modelling with EU JRC PVGIS v5.3 data):

Set-up London Manchester Glasgow
Facing south, tilted 35° (frame or ground mount) 815 kWh 709 kWh 682 kWh
Facing south, vertical (balcony railing or wall) 594 kWh 517 kWh 506 kWh
Facing east, vertical 417 kWh 367 kWh 343 kWh
Facing west, vertical 399 kWh 355 kWh 348 kWh
Facing north, vertical 162 kWh 155 kWh 150 kWh

Source: our PVGIS dataset (CSV); method.

How we got these: PVGIS gives output per 1 kWp of panels. We multiplied by 0.8 for an 800 Wp kit. The full method is at the end of this page.

Try your own location, direction and angle in the plug-in solar calculator.

What the government’s example assumes

The Department for Energy Security and Net Zero (DESNZ) published an example in its impact assessment for the new rules. It assumes an 800 W kit, average UK sunshine, little or no shading, no battery and nothing paid for export, and an average GB household using 3,323 kWh a year with someone at home during the day (DESNZ impact assessment, para 34).

DESNZ example Maximum output a year Used in the home a year Share used
30°, facing south 690 kWh 428 kWh 62%
Vertical, facing east/west 378 kWh 272 kWh 72%

Source: DESNZ impact assessment, Table 7.

These are the government’s figures, not ours. Our PVGIS numbers sit close to them. Our Manchester figure for 35° south (709 kWh) is near DESNZ’s 690 kWh, and our vertical east/west average for Newcastle (378 kWh) matches its 378 kWh. London and the south-west come out higher, and Glasgow lower. That is what you’d expect, since DESNZ used average UK sunshine.

The Energy Saving Trust (EST) gives a similar figure: about 700 kWh a year for an 800 W kit in Manchester, facing south at 30°, with no shade (Energy Saving Trust).

Annual output by UK location

Average kWh a year for 800 Wp of panels, no shading, before clipping. “East/west vertical” is the average of the east and west rows, which is how a kit split across two sides would roughly behave.

Location South 35° South 15° South vertical East vertical West vertical East/west vertical (average)
Plymouth 897 841 636 439 444 442
Cardiff 833 781 596 402 421 412
London 815 761 594 417 399 408
Birmingham 774 723 568 397 384 391
Newcastle 758 699 572 381 376 378
Aberdeen 715 657 545 349 352 351
Manchester 709 665 517 367 355 361
Glasgow 682 637 506 343 348 346

Source: our PVGIS dataset (CSV).

Weather changes from year to year. PVGIS gives a year-to-year standard deviation for each case. For a 35° south-facing 800 Wp kit, it works out at about 21 kWh in Glasgow and about 34 kWh in London, or roughly 3–4% of the average. If yearly output follows a normal bell curve, about two years in three land within that band of the average (dataset).

Northern Ireland is not in these tables. The August 2026 change does not yet let you use plug-in solar there. It would need a separate change to Northern Ireland’s own electricity safety regulations, which is a decision for the NI Executive (DESNZ impact assessment, para 12).

Does direction matter?

Yes, a lot. Here is London and Glasgow for six directions, at 35° and vertical (800 Wp, no shade):

Yearly output of an 800 Wp plug-in kit in London by direction, tilted 35° and vertical Bar chart of kWh a year in London. South: 815 at 35°, 594 vertical; South-east: 775 at 35°, 559 vertical; South-west: 757 at 35°, 536 vertical; East: 654 at 35°, 417 vertical; West: 630 at 35°, 399 vertical; North: 433 at 35°, 162 vertical. Does direction matter? London 800 Wp of panels in London, no shade. kWh ayear.Tilted 35° (frame)Vertical (railing, wall)South815594South-east775559South-west757536East654417West630399North4331620300600900kWhWattleigh modelling of EU JRC PVGIS data · wattleigh.com
Wattleigh modelling: kWh a year in London by direction and angle, 800 Wp, no shade. Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, checked 10 October 2026. Per-kWp output × 0.8. No shading and no 800 W clipping modelled.
Direction London 35° London vertical Glasgow 35° Glasgow vertical
South 815 594 682 506
South-east 775 559 639 461
South-west 757 536 645 467
East 654 417 538 343
West 630 399 546 348
North 433 162 375 150

Source: our PVGIS dataset (CSV).

What this shows:

  • South-east and south-west lose little. At 35°, they make about 5–7% less than due south.
  • East and west make about 20–23% less than south when tilted at 35°, and about 30–33% less when vertical. But their output is spread across the morning or the afternoon, which can help you use more of it at home. In the DESNZ example, the vertical east/west household used 72% of its output, against 62% for the south-facing one (DESNZ impact assessment, Table 7).
  • North-facing and vertical is poor: about 145–165 kWh a year across our eight locations. A north-facing balcony is rarely a good spot for a kit.

Does angle matter?

It depends on the direction.

London, 800 Wp Low tilt (15°) Tilted (35°) Vertical (90°)
South 761 815 594
East 674 654 417
West 662 630 399

Source: our PVGIS dataset (CSV).

  • Facing south, 35° is the best of the three. Vertical panels make about 27% less across the year.
  • Facing east or west, a lower tilt does slightly better than 35°, and vertical panels make about 36–37% less than at 35°.
  • A balcony railing is usually close to vertical. That is the main reason balcony kits make less than kits on a frame in the garden. Our balcony solar guide covers what that means in practice.

We did not model other angles, such as 65°. Our dataset has 15°, 35° and 90° only. A panel tilted somewhere between would land between those columns.

Month by month

Monthly output of an 800 Wp plug-in kit facing south at 35°: London, Manchester and Glasgow Line chart of average kWh per month, January to December. London: January 33, February 43, March 69, April 92, May 96, June 98, July 99, August 88, September 76, October 55, November 39, December 29 (815 kWh a year). Manchester: January 22, February 36, March 62, April 84, May 90, June 89, July 86, August 78, September 65, October 45, November 30, December 23 (709 kWh a year). Glasgow: January 19, February 32, March 58, April 82, May 93, June 88, July 89, August 77, September 60, October 42, November 27, December 16 (682 kWh a year). Output peaks from May to July and is lowest in December. Month by month: south, 35° 800 Wp of panels facing south, tilted 35°, noshade. Average kWh per month.London815 kWh a yearManchester709 kWh a yearGlasgow682 kWh a yearkWh020406080100120JanJFebFMarMAprAMayMJunJJulJAugASepSOctONovNDecDkWh in June and DecemberJuneDecemberLondon9829Manchester8923Glasgow8816Wattleigh modelling of EU JRC PVGIS data · wattleigh.com
Wattleigh modelling: average kWh per month, 800 Wp facing south at 35°, no shade. Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, checked 10 October 2026. Per-kWp output × 0.8. No shading and no 800 W clipping modelled.

Average kWh per month for an 800 Wp kit, no shade (Wattleigh modelling with EU JRC PVGIS data):

Month London S 35° Manchester S 35° Glasgow S 35° London S vertical London E vertical
Jan 33 22 19 37 10
Feb 43 36 32 42 18
Mar 69 62 58 57 34
Apr 92 84 82 62 50
May 96 90 93 53 56
Jun 98 89 88 50 57
Jul 99 86 89 52 58
Aug 88 78 77 55 50
Sep 76 65 60 58 39
Oct 55 45 42 51 24
Nov 39 30 27 42 13
Dec 29 23 16 35 8
Year 815 709 682 594 417

Source: our PVGIS dataset (CSV). Monthly values are rounded, so they may not add up exactly to the yearly total.

Three things stand out:

  1. Winter is thin. For a 35° south-facing kit, November to February gives about 18% of the year’s output in London and about 14% in Glasgow.
  2. Per day, a 35° south-facing kit in London averages about 3.3 kWh a day in June and about 0.9 kWh a day in December. In Glasgow it is about 2.9 kWh a day in June and about 0.5 kWh a day in December.
  3. Vertical south-facing panels hold up better in winter. In London they beat the 35° panel from November to January and roughly match it in February, because the winter sun is low. They lose out heavily in summer.
Monthly output of an 800 Wp plug-in kit in London: south at 35°, south vertical and east vertical Line chart of average kWh per month in London, January to December. South, 35°: January 33, February 43, March 69, April 92, May 96, June 98, July 99, August 88, September 76, October 55, November 39, December 29 (815 kWh a year). South, vertical: January 37, February 42, March 57, April 62, May 53, June 50, July 52, August 55, September 58, October 51, November 42, December 35 (594 kWh a year). East, vertical: January 10, February 18, March 34, April 50, May 56, June 57, July 58, August 50, September 39, October 24, November 13, December 8 (417 kWh a year). Vertical south-facing panels beat the 35° panel from November to January because the winter sun is low, but make much less in summer. Month by month: London, by angle 800 Wp of panels in London, no shade. AveragekWh per month.South, 35° (frame)815 kWh a yearSouth, vertical (railing)594 kWh a yearEast, vertical417 kWh a yearkWh020406080100120JanJFebFMarMAprAMayMJunJJulJAugASepSOctONovNDecDkWh in June and DecemberJuneDecemberSouth, 35°9829South, vertical5035East, vertical578Vertical south-facing panels beat the 35°panel from November to January, when the sunis low, but make much less in summer.Wattleigh modelling of EU JRC PVGIS data · wattleigh.com
Wattleigh modelling: London, 800 Wp, no shade. Vertical south-facing panels do better in mid-winter, when the sun is low, but much worse in summer. Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, checked 10 October 2026. Per-kWp output × 0.8. No shading and no 800 W clipping modelled.

Bigger panels, same 800 W limit

A legal kit’s inverter can feed at most 800 W into your home’s wiring. The product spec also caps it at 800 VA and 3.5 A (DESNZ product spec v2, 4.1). Kits can include up to 2,000 W of panels (up to four panels), but the inverter still limits what reaches your sockets to 800 W (product spec v2, 4.1 and 4.2.2). So a kit with, for example, 2 × 445 Wp panels (890 Wp) is within the spec.

When the panels could produce more than 800 W, the inverter trims the extra. This is called clipping. It mostly happens around midday on bright summer days, and mostly with tilted south-facing panels. How the limit works: the 800 W limit explained.

Important: the tables on this page show output before clipping. For kits above 800 Wp they are upper bounds: real output will be lower than shown, and the gap grows as the panels get bigger. Our calculator gives an approximate clipping estimate based on monthly data, which likely overstates the loss. We have not yet done hourly modelling.

Panels (Wp) London S 35°, before clipping London E vertical, before clipping
600 611 kWh 313 kWh
800 815 kWh 417 kWh
890 907 kWh (upper bound) 464 kWh (upper bound)
1,200 1,223 kWh (upper bound) 626 kWh (upper bound)

Wattleigh modelling: per-kWp value × panel size, no clipping applied (dataset; method).

We have left out 2,000 Wp. A simple multiplication would overstate it by too much to be useful. We will add clipped figures to this page when we have run PVGIS hourly data.

In general, extra panels are likely to help most where the panels rarely reach full power: vertical, east- or west-facing, or in winter. They help least on a tilted south-facing frame in summer. This is our reasoning, not a measured result.

If your kit has more than 960 W of panels, the official spec says you should consider having a qualified electrician check your wiring first (product spec v2, 4.1). Our rules page explains the 800 W limit in more detail.

From kWh to pounds

Generation is not the same as savings. You only save on the electricity you use at home while the panels are generating.

  • Your rate: We use Ofgem’s price cap for 1 October to 31 December 2026: 26.32p per kWh for electricity (GB average, Direct Debit, no VAT on electricity until 31 March 2027). Your own tariff may differ (Ofgem price cap).
  • Example: a London kit making 594 kWh a year (vertical, south), in a home where people are in and out and use 45–60% of it (our assumption), saves about 594 × 0.45 × £0.2632 ≈ £70 to 594 × 0.60 × £0.2632 ≈ £94 a year.
  • Spare power: Don’t count on being paid for electricity you export. The Smart Export Guarantee needs an MCS-certified installation, which plug-in kits normally don’t have (DESNZ impact assessment, paras 32 and 61).
  • Batteries: plug-in batteries, and plug-in solar kits with a built-in or add-on battery, are not covered by the new rules and must not be connected under this route (product spec v2, section 1).

For full worked examples with payback, see Are plug-in solar panels worth it?. For your own set-up, use the plug-in solar calculator.

How we calculated these numbers

  • Tool: EU Joint Research Centre PVGIS, version 5.3, PVcalc endpoint (https://re.jrc.ec.europa.eu/api/v5_3/PVcalc).
  • Weather data: PVGIS-SARAH3 solar radiation and ERA5 weather data, years 2005–2023. The horizon (distant hills) is included.
  • Settings: 1 kWp crystalline silicon panels, free-standing mounting, 14% system losses (PVGIS default). Results scaled ×0.8 for an 800 Wp kit.
  • Grid: 8 city-centre locations × 6 directions × 3 tilts (15°, 35°, 90°).
  • Retrieved: 10 October 2026.
  • Not modelled in these tables: clipping at the 800 W inverter limit (the calculator gives an approximate estimate from monthly data that likely overstates the loss; hourly modelling is not done yet), nearby shading (trees, walls, the balcony above), dirt, and the extra heat of panels mounted against a wall. Treat every figure as an upper reference for an unshaded spot.
  • Download: plug-in solar output per kWp, 8 UK locations (CSV).

Cite as: “Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, checked 2026-10-10.” More on our method: How we research.

Why your real output may differ

  • Shading. Even partial shade from a balcony above, a side wall or a tree can cut output noticeably. Our tables assume none.
  • Mounting heat. Panels against a wall or railing run hotter than free-standing ones, and hot panels make a little less. PVGIS’s free-standing setting does not capture this.
  • Dirt and bird droppings, especially on low-tilt panels.
  • Your monitoring app or meter may measure at a different point from PVGIS.
  • The weather that year. See the year-to-year variation above.

Who these figures won’t fit

  • Heavily shaded spots. If your panels are in shade for much of the day, expect noticeably less than any figure here.
  • Northern Ireland. Not covered by the new rules yet.
  • Kits with more than 800 Wp of panels. Our tables show those before clipping, so they are upper bounds. The calculator’s clipping estimate is approximate and likely overstates the loss.
  • Kits with a battery. Not allowed under the plug-in route, so we don’t model them.

Next step


Evidence: researched (modelled from public data, not measured by us).

Common questions

How many kWh does an 800 W solar kit make a day in the UK?
It depends on the season more than anything. For a 35° south-facing 800 Wp kit, our modelling gives about 3.3 kWh a day in June and 0.9 kWh a day in December in London, and about 2.9 and 0.5 kWh a day in Glasgow. Dividing the yearly total by 365 hides that swing.
How much does a vertical balcony panel produce?
With 800 Wp of panels and no shade, about 500–640 kWh a year facing south and about 340–440 kWh a year facing east or west, depending on where you live. See the location table above.
Is it worth having more than 800 W of panels?
Extra panels can raise output on dull days and on vertical or east/west set-ups, but the inverter caps what reaches your sockets at 800 W. Our tables are before clipping, so figures above 800 Wp are upper bounds. The calculator gives an approximate clipping estimate from monthly data that likely overstates the loss, and hourly modelling is not done yet. Above 960 W of panels, the official spec says you should consider having a qualified electrician check your wiring first.
How much less do you get in Scotland?
For a 35° south-facing kit, Glasgow gets about 16% less than London over a year (682 vs 815 kWh) and Aberdeen about 12% less (715 kWh). The gap is much wider in winter.
How much does a kit make in December?
For an 800 Wp kit facing south at 35°: about 29 kWh in London, 23 kWh in Manchester and 16 kWh in Glasgow. A vertical south-facing kit in London makes about 35 kWh.

Keep reading

Everything in Savings

Who wrote this

Wattleigh Editorial Team

The Wattleigh Editorial Team researches and writes every guide on this site. We work from official sources (legislation.gov.uk, DESNZ, Ofgem, the Energy Networks Association, Electrical Safety First) and show the date we last checked the rules on each page. Our guides are researched, not hands-on tested.

How we research and check the rules