How much electricity does a plug-in solar kit generate in the UK?
Annual and monthly kWh for an 800 W plug-in solar kit in 8 UK cities, by direction and angle. Open EU JRC PVGIS data, assumptions shown.
How we're paid: We don't earn from any retailer on this page yet. If that changes, this line will say so. How we make money
Quick answer
How much electricity does plug-in solar generate? The short answer: with 800 W of panels and no shade, an 800 W plug-in kit in Great Britain makes roughly 680–900 kWh a year when the panels face south and are tilted at 35°. Hung vertically on an east- or west-facing railing, it makes roughly 340–440 kWh a year.
Based on: EU JRC PVGIS v5.3 data (retrieved 10 October 2026) and the DESNZ impact assessment

Data: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, retrieved 10 October 2026. We have not tested kits ourselves. These figures come from modelling, not measurement.
New to plug-in solar? Start with the complete guide.
Output is lower in Scotland than in the south of England, and only a small share of it comes in December. The government’s own example uses 690 kWh a year for a 30° south-facing kit and 378 kWh a year for a vertical east/west kit (DESNZ impact assessment, Table 7). Our figures are Wattleigh modelling with EU JRC PVGIS data (dataset; method). Your real result will usually be lower if anything shades the panels.
The short answer in one table
Average yearly output for a kit with 800 Wp of panels, no shading, before any 800 W inverter clipping (Wattleigh modelling with EU JRC PVGIS v5.3 data):
| Set-up | London | Manchester | Glasgow |
|---|---|---|---|
| Facing south, tilted 35° (frame or ground mount) | 815 kWh | 709 kWh | 682 kWh |
| Facing south, vertical (balcony railing or wall) | 594 kWh | 517 kWh | 506 kWh |
| Facing east, vertical | 417 kWh | 367 kWh | 343 kWh |
| Facing west, vertical | 399 kWh | 355 kWh | 348 kWh |
| Facing north, vertical | 162 kWh | 155 kWh | 150 kWh |
Source: our PVGIS dataset (CSV); method.
How we got these: PVGIS gives output per 1 kWp of panels. We multiplied by 0.8 for an 800 Wp kit. The full method is at the end of this page.
Try your own location, direction and angle in the plug-in solar calculator.
What the government’s example assumes
The Department for Energy Security and Net Zero (DESNZ) published an example in its impact assessment for the new rules. It assumes an 800 W kit, average UK sunshine, little or no shading, no battery and nothing paid for export, and an average GB household using 3,323 kWh a year with someone at home during the day (DESNZ impact assessment, para 34).
| DESNZ example | Maximum output a year | Used in the home a year | Share used |
|---|---|---|---|
| 30°, facing south | 690 kWh | 428 kWh | 62% |
| Vertical, facing east/west | 378 kWh | 272 kWh | 72% |
Source: DESNZ impact assessment, Table 7.
These are the government’s figures, not ours. Our PVGIS numbers sit close to them. Our Manchester figure for 35° south (709 kWh) is near DESNZ’s 690 kWh, and our vertical east/west average for Newcastle (378 kWh) matches its 378 kWh. London and the south-west come out higher, and Glasgow lower. That is what you’d expect, since DESNZ used average UK sunshine.
The Energy Saving Trust (EST) gives a similar figure: about 700 kWh a year for an 800 W kit in Manchester, facing south at 30°, with no shade (Energy Saving Trust).
Annual output by UK location
Average kWh a year for 800 Wp of panels, no shading, before clipping. “East/west vertical” is the average of the east and west rows, which is how a kit split across two sides would roughly behave.
| Location | South 35° | South 15° | South vertical | East vertical | West vertical | East/west vertical (average) |
|---|---|---|---|---|---|---|
| Plymouth | 897 | 841 | 636 | 439 | 444 | 442 |
| Cardiff | 833 | 781 | 596 | 402 | 421 | 412 |
| London | 815 | 761 | 594 | 417 | 399 | 408 |
| Birmingham | 774 | 723 | 568 | 397 | 384 | 391 |
| Newcastle | 758 | 699 | 572 | 381 | 376 | 378 |
| Aberdeen | 715 | 657 | 545 | 349 | 352 | 351 |
| Manchester | 709 | 665 | 517 | 367 | 355 | 361 |
| Glasgow | 682 | 637 | 506 | 343 | 348 | 346 |
Source: our PVGIS dataset (CSV).
Weather changes from year to year. PVGIS gives a year-to-year standard deviation for each case. For a 35° south-facing 800 Wp kit, it works out at about 21 kWh in Glasgow and about 34 kWh in London, or roughly 3–4% of the average. If yearly output follows a normal bell curve, about two years in three land within that band of the average (dataset).
Northern Ireland is not in these tables. The August 2026 change does not yet let you use plug-in solar there. It would need a separate change to Northern Ireland’s own electricity safety regulations, which is a decision for the NI Executive (DESNZ impact assessment, para 12).
Does direction matter?
Yes, a lot. Here is London and Glasgow for six directions, at 35° and vertical (800 Wp, no shade):
| Direction | London 35° | London vertical | Glasgow 35° | Glasgow vertical |
|---|---|---|---|---|
| South | 815 | 594 | 682 | 506 |
| South-east | 775 | 559 | 639 | 461 |
| South-west | 757 | 536 | 645 | 467 |
| East | 654 | 417 | 538 | 343 |
| West | 630 | 399 | 546 | 348 |
| North | 433 | 162 | 375 | 150 |
Source: our PVGIS dataset (CSV).
What this shows:
- South-east and south-west lose little. At 35°, they make about 5–7% less than due south.
- East and west make about 20–23% less than south when tilted at 35°, and about 30–33% less when vertical. But their output is spread across the morning or the afternoon, which can help you use more of it at home. In the DESNZ example, the vertical east/west household used 72% of its output, against 62% for the south-facing one (DESNZ impact assessment, Table 7).
- North-facing and vertical is poor: about 145–165 kWh a year across our eight locations. A north-facing balcony is rarely a good spot for a kit.
Does angle matter?
It depends on the direction.
| London, 800 Wp | Low tilt (15°) | Tilted (35°) | Vertical (90°) |
|---|---|---|---|
| South | 761 | 815 | 594 |
| East | 674 | 654 | 417 |
| West | 662 | 630 | 399 |
Source: our PVGIS dataset (CSV).
- Facing south, 35° is the best of the three. Vertical panels make about 27% less across the year.
- Facing east or west, a lower tilt does slightly better than 35°, and vertical panels make about 36–37% less than at 35°.
- A balcony railing is usually close to vertical. That is the main reason balcony kits make less than kits on a frame in the garden. Our balcony solar guide covers what that means in practice.
We did not model other angles, such as 65°. Our dataset has 15°, 35° and 90° only. A panel tilted somewhere between would land between those columns.
Month by month
Average kWh per month for an 800 Wp kit, no shade (Wattleigh modelling with EU JRC PVGIS data):
| Month | London S 35° | Manchester S 35° | Glasgow S 35° | London S vertical | London E vertical |
|---|---|---|---|---|---|
| Jan | 33 | 22 | 19 | 37 | 10 |
| Feb | 43 | 36 | 32 | 42 | 18 |
| Mar | 69 | 62 | 58 | 57 | 34 |
| Apr | 92 | 84 | 82 | 62 | 50 |
| May | 96 | 90 | 93 | 53 | 56 |
| Jun | 98 | 89 | 88 | 50 | 57 |
| Jul | 99 | 86 | 89 | 52 | 58 |
| Aug | 88 | 78 | 77 | 55 | 50 |
| Sep | 76 | 65 | 60 | 58 | 39 |
| Oct | 55 | 45 | 42 | 51 | 24 |
| Nov | 39 | 30 | 27 | 42 | 13 |
| Dec | 29 | 23 | 16 | 35 | 8 |
| Year | 815 | 709 | 682 | 594 | 417 |
Source: our PVGIS dataset (CSV). Monthly values are rounded, so they may not add up exactly to the yearly total.
Three things stand out:
- Winter is thin. For a 35° south-facing kit, November to February gives about 18% of the year’s output in London and about 14% in Glasgow.
- Per day, a 35° south-facing kit in London averages about 3.3 kWh a day in June and about 0.9 kWh a day in December. In Glasgow it is about 2.9 kWh a day in June and about 0.5 kWh a day in December.
- Vertical south-facing panels hold up better in winter. In London they beat the 35° panel from November to January and roughly match it in February, because the winter sun is low. They lose out heavily in summer.
Bigger panels, same 800 W limit
A legal kit’s inverter can feed at most 800 W into your home’s wiring. The product spec also caps it at 800 VA and 3.5 A (DESNZ product spec v2, 4.1). Kits can include up to 2,000 W of panels (up to four panels), but the inverter still limits what reaches your sockets to 800 W (product spec v2, 4.1 and 4.2.2). So a kit with, for example, 2 × 445 Wp panels (890 Wp) is within the spec.
When the panels could produce more than 800 W, the inverter trims the extra. This is called clipping. It mostly happens around midday on bright summer days, and mostly with tilted south-facing panels. How the limit works: the 800 W limit explained.
Important: the tables on this page show output before clipping. For kits above 800 Wp they are upper bounds: real output will be lower than shown, and the gap grows as the panels get bigger. Our calculator gives an approximate clipping estimate based on monthly data, which likely overstates the loss. We have not yet done hourly modelling.
| Panels (Wp) | London S 35°, before clipping | London E vertical, before clipping |
|---|---|---|
| 600 | 611 kWh | 313 kWh |
| 800 | 815 kWh | 417 kWh |
| 890 | 907 kWh (upper bound) | 464 kWh (upper bound) |
| 1,200 | 1,223 kWh (upper bound) | 626 kWh (upper bound) |
Wattleigh modelling: per-kWp value × panel size, no clipping applied (dataset; method).
We have left out 2,000 Wp. A simple multiplication would overstate it by too much to be useful. We will add clipped figures to this page when we have run PVGIS hourly data.
In general, extra panels are likely to help most where the panels rarely reach full power: vertical, east- or west-facing, or in winter. They help least on a tilted south-facing frame in summer. This is our reasoning, not a measured result.
If your kit has more than 960 W of panels, the official spec says you should consider having a qualified electrician check your wiring first (product spec v2, 4.1). Our rules page explains the 800 W limit in more detail.
From kWh to pounds
Generation is not the same as savings. You only save on the electricity you use at home while the panels are generating.
- Your rate: We use Ofgem’s price cap for 1 October to 31 December 2026: 26.32p per kWh for electricity (GB average, Direct Debit, no VAT on electricity until 31 March 2027). Your own tariff may differ (Ofgem price cap).
- Example: a London kit making 594 kWh a year (vertical, south), in a home where people are in and out and use 45–60% of it (our assumption), saves about 594 × 0.45 × £0.2632 ≈ £70 to 594 × 0.60 × £0.2632 ≈ £94 a year.
- Spare power: Don’t count on being paid for electricity you export. The Smart Export Guarantee needs an MCS-certified installation, which plug-in kits normally don’t have (DESNZ impact assessment, paras 32 and 61).
- Batteries: plug-in batteries, and plug-in solar kits with a built-in or add-on battery, are not covered by the new rules and must not be connected under this route (product spec v2, section 1).
For full worked examples with payback, see Are plug-in solar panels worth it?. For your own set-up, use the plug-in solar calculator.
How we calculated these numbers
- Tool: EU Joint Research Centre PVGIS, version 5.3,
PVcalcendpoint (https://re.jrc.ec.europa.eu/api/v5_3/PVcalc). - Weather data: PVGIS-SARAH3 solar radiation and ERA5 weather data, years 2005–2023. The horizon (distant hills) is included.
- Settings: 1 kWp crystalline silicon panels, free-standing mounting, 14% system losses (PVGIS default). Results scaled ×0.8 for an 800 Wp kit.
- Grid: 8 city-centre locations × 6 directions × 3 tilts (15°, 35°, 90°).
- Retrieved: 10 October 2026.
- Not modelled in these tables: clipping at the 800 W inverter limit (the calculator gives an approximate estimate from monthly data that likely overstates the loss; hourly modelling is not done yet), nearby shading (trees, walls, the balcony above), dirt, and the extra heat of panels mounted against a wall. Treat every figure as an upper reference for an unshaded spot.
- Download: plug-in solar output per kWp, 8 UK locations (CSV).
Cite as: “Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, checked 2026-10-10.” More on our method: How we research.
Why your real output may differ
- Shading. Even partial shade from a balcony above, a side wall or a tree can cut output noticeably. Our tables assume none.
- Mounting heat. Panels against a wall or railing run hotter than free-standing ones, and hot panels make a little less. PVGIS’s free-standing setting does not capture this.
- Dirt and bird droppings, especially on low-tilt panels.
- Your monitoring app or meter may measure at a different point from PVGIS.
- The weather that year. See the year-to-year variation above.
Who these figures won’t fit
- Heavily shaded spots. If your panels are in shade for much of the day, expect noticeably less than any figure here.
- Northern Ireland. Not covered by the new rules yet.
- Kits with more than 800 Wp of panels. Our tables show those before clipping, so they are upper bounds. The calculator’s clipping estimate is approximate and likely overstates the loss.
- Kits with a battery. Not allowed under the plug-in route, so we don’t model them.
Next step
- Put in your own location, direction and angle: plug-in solar calculator.
- See what that output is worth: Are plug-in solar panels worth it?
Evidence: researched (modelled from public data, not measured by us).
Common questions
- How many kWh does an 800 W solar kit make a day in the UK?
- It depends on the season more than anything. For a 35° south-facing 800 Wp kit, our modelling gives about 3.3 kWh a day in June and 0.9 kWh a day in December in London, and about 2.9 and 0.5 kWh a day in Glasgow. Dividing the yearly total by 365 hides that swing.
- How much does a vertical balcony panel produce?
- With 800 Wp of panels and no shade, about 500–640 kWh a year facing south and about 340–440 kWh a year facing east or west, depending on where you live. See the location table above.
- Is it worth having more than 800 W of panels?
- Extra panels can raise output on dull days and on vertical or east/west set-ups, but the inverter caps what reaches your sockets at 800 W. Our tables are before clipping, so figures above 800 Wp are upper bounds. The calculator gives an approximate clipping estimate from monthly data that likely overstates the loss, and hourly modelling is not done yet. Above 960 W of panels, the official spec says you should consider having a qualified electrician check your wiring first.
- How much less do you get in Scotland?
- For a 35° south-facing kit, Glasgow gets about 16% less than London over a year (682 vs 815 kWh) and Aberdeen about 12% less (715 kWh). The gap is much wider in winter.
- How much does a kit make in December?
- For an 800 Wp kit facing south at 35°: about 29 kWh in London, 23 kWh in Manchester and 16 kWh in Glasgow. A vertical south-facing kit in London makes about 35 kWh.
Keep reading
Does plug-in solar work in winter and on cloudy days?
Yes, but far less. October–March output for an 800 W kit, why an upright panel beats a tilted one in December, and what winter output is worth.
How much do plug-in solar panels cost? UK prices and the extras
UK plug-in solar kit prices with seller and date, the extras sellers leave out, VAT, and what each kit costs per unit of electricity you actually use.
Are plug-in solar panels worth it in the UK?
Worked examples for three UK homes at the current Ofgem cap: yearly savings ranges, payback, and when a plug-in solar kit is not worth it.
The Wattleigh Editorial Team researches and writes every guide on this site. We work from official sources (legislation.gov.uk, DESNZ, Ofgem, the Energy Networks Association, Electrical Safety First) and show the date we last checked the rules on each page. Our guides are researched, not hands-on tested.