Skip to content
Wattleigh

Plug-in solar glossary: the terms explained

ResearchedRules checked See the rules

By Wattleigh Editorial Team · Last updated

These are the words you’ll meet when you read about plug-in solar in the UK, from AC to VA, in plain English. Where a term involves a rule, we use the wording from our rules sheet and show the date we last checked it. Each term has its own link, so you can share it or jump straight to it.

AC and DC

DC (direct current) is electricity that flows one way. Solar panels make DC. AC (alternating current) changes direction many times a second. It’s what comes out of your wall sockets, at about 230 V and 50 Hz in the UK. A plug-in kit needs an inverter to turn the panels’ DC into AC your home can use. The UK’s 800 W limit applies to the AC side: what the inverter feeds into your wiring. See microinverter and clipping.

Anti-islanding

Anti-islanding is the safety feature that stops a solar inverter from feeding power when the mains supply is off. This protects people working on the network and anyone touching the plug. The UK product spec requires the inverter to disconnect from the mains within 100 milliseconds. The voltage at the plug pins must drop below 34 V within 100 milliseconds of being unplugged (DESNZ product spec v2). It also means a plug-in kit won’t keep your lights on in a power cut.

Clipping

Clipping happens when the panels could make more power than the inverter is allowed to deliver. A legal kit’s inverter can feed at most 800 W into your home’s wiring. So a kit with, say, 950 W of panels is “clipped” to 800 W on the brightest summer middays. The extra panel watts still help on dull days, in winter and early or late in the day, which is why many kits have more than 800 W of panels. Our guide to how much electricity plug-in solar generates shows the trade-off, and our calculator gives a rough estimate of it.

Consumer unit

The consumer unit (often called the fuse box or fuse board) is where your home’s electricity is split into circuits, each protected by a breaker or fuse. Legal kits come with a durable label to stick at or near the consumer unit, showing that a plug-in solar device is connected (DESNZ product spec v2). Checking what’s in your consumer unit is also the first safety step (see RCD, RCBO and MCB).

DNO (distribution network operator)

Your DNO is the company that runs the local electricity network (the cables and substations) in your area. It isn’t the supplier that sends your bills. Great Britain has several DNOs, each covering its own region. You must register your kit so your local network operator knows it’s there, and tell them again if you permanently remove it. Registering is done online (see registration). Rules checked: 11 October 2026 (Ofgem G98 decision).

ENA (Energy Networks Association)

ENA stands for the Energy Networks Association. For plug-in solar, you’ll mostly meet the name in two places: the ENA Type Test Register, where a legal kit must show as Compliant, and ENA Connect Direct, the website that hosts the register (ENA Type Test Register). Some guides call kit registration registering “on the ENA website”. The official guidance names the UK Plug-in Solar Registration website for that step (see registration).

ENA Type Test Register

The ENA Type Test Register is a public list of generating devices that have been tested to the network rules. Every legal kit must be type-tested to the G98 network standard and shown as “Compliant” on the register before it can be sold. Being listed isn’t enough on its own: the entry has to say Compliant (DESNZ product spec v2). It’s free to search and needs no login (ENA Type Test Register). Our guide shows how: check a kit is compliant. Rules checked: .

EREC G98

Engineering Recommendation G98 is the Great Britain network rule for connecting small generators, such as solar, that produce up to 16 A per phase. In August 2026 Ofgem approved a change to G98 for plug-in microgenerators. It lets householders install a compliant kit themselves and requires them to notify their network operator (Ofgem G98 decision). G98 is also where the “one kit per household” limit comes from. G98 covers Great Britain only; Northern Ireland has its own version. Rules checked: .

G99

Engineering Recommendation G99 covers larger generators, above G98’s 16 A per phase limit. Already have rooftop solar? A plug-in kit can still be allowed, but only if your total generation stays within the G98 limit (16 A per phase). Above that, G99 applies. Check with your installer or network operator first (Ofgem G98 decision). Rules checked: .

Household

In the plug-in solar rules, a household is “A single dwelling unit with its own electricity supply and consumer unit.” In a block of flats or a converted house, each flat with its own consumer unit counts as a separate household (DESNZ product spec v2). This matters because, right now, you can connect one plug-in solar kit per household. The government plans to allow one per circuit later, but only once the network rules (G98) change. Rules checked: .

IPS (Interim Product Specification)

The Plug-in Solar Device Interim Product Specification is the government’s technical rulebook for plug-in kits. The law only covers kits built to version 2 (July 2026). A kit that doesn’t meet it isn’t covered, whatever the listing says (SI 2026/848). The spec covers the 800 VA and 3.5 A limits, the plug and fuse, anti-islanding, mounting, labels and instructions. Version 1 (June 2026) has been withdrawn. Rules checked: .

kWh (kilowatt-hour)

A kilowatt-hour is the unit of energy on your electricity bill. It’s 1,000 watts used or made for one hour, such as an 800 W kit running at full output for 75 minutes. Watts measure power at a moment; kilowatt-hours measure energy over time. Solar output and savings are measured in kWh per year. Your saving depends on how many of those kWh you use at home (see self-consumption) and on your unit rate (see Ofgem price cap).

kWp and Wp (peak watts)

Wp (watt-peak) is a panel’s rated output under standard laboratory test conditions: strong light at a set temperature. kWp is 1,000 Wp. A “2 × 445 W” kit has 890 Wp of panels. Real panels rarely reach their Wp rating in the UK. Kits can include up to 2,000 W of panels (up to four panels), but the inverter still limits what reaches your sockets to 800 W. Rules checked: .

MCS (Microgeneration Certification Scheme)

MCS describes itself as “the UK’s quality mark for small-scale renewable energy systems”. Its certification covers products, installers and finished installations (MCS, who we are). Plug-in kits that you fit yourself normally don’t have MCS certification, which is why most can’t use the Smart Export Guarantee (DESNZ impact assessment).

Microinverter

A microinverter is a small inverter, usually fixed behind or beside the panels. It converts their DC into mains-quality AC and matches it to the grid’s voltage and frequency. In a plug-in kit, the microinverter is the part that sets the legal limit: its rated AC output must not exceed 800 W, with apparent power of no more than 800 VA and current of no more than 3.5 A. It also provides anti-islanding. The plug lead runs from the microinverter to your socket (DESNZ product spec v2).

MPAN (meter point administration number)

Your MPAN is the unique reference for your home’s electricity supply point. Octopus Energy describes it as the “unique ‘address’ for your electricity supply”. It’s printed on your bill in a grid of boxes starting with a large “S”. The bottom 13 digits are the core number most forms ask for (Octopus Energy, what is an MPAN?). Suppliers may ask for it if you set up an export tariff. The official guidance we’ve read lists only your name, postcode and the kit’s make and model for plug-in registration.

Ofgem price cap

Ofgem says the price cap “is the maximum amount your supplier can charge for a unit of energy and standing charge together”. It applies to standard variable tariffs, and it doesn’t cap your total bill. It’s reset every three months (Ofgem, energy price cap). We use Ofgem’s price cap for 1 October to 31 December 2026: 26.32p per kWh for electricity (GB average, Direct Debit, no VAT on electricity until 31 March 2027). Your own tariff may differ (Ofgem price cap).

Permitted development

Permitted development rights let you do some building work without applying for planning permission, within set limits. In England, planning rules updated on 27 August 2026 cover plug-in solar under the existing permitted development rights for home solar. Plug-in panels must not be fitted to a wooden wall, wooden balcony, wooden fence or gate, or timber-clad walls. Listed buildings, and walls facing a road in conservation areas, are excluded (SI 2026/896). Wales and Scotland have their own planning rules and haven’t made a plug-in-specific change, so check your council’s guidance. Rules checked: . More in the rules.

PVGIS

PVGIS (Photovoltaic Geographical Information System) is a free online tool from the European Commission’s Joint Research Centre. It estimates how much electricity a solar panel would make at a given place, angle and direction, using years of satellite weather data. We use PVGIS figures for our output estimates and our calculator. They’re estimates for an unshaded spot, not a guarantee (EU JRC PVGIS).

RCD, RCBO and MCB

These are the protective devices in your consumer unit. An MCB (miniature circuit breaker) cuts the power if a circuit is overloaded or short-circuits. An RCD (residual current device) cuts the power fast if current leaks to earth, for example through a person, and often protects several circuits at once. An RCBO combines both for a single circuit. What to check in your own consumer unit before using plug-in solar is covered in is plug-in solar safe?

Registration (myplugin.solar)

Registration is how you tell the network that your kit is there. Register your kit before you start using it: install it, register it, then switch it on. The official guidance says registering is a legal requirement, and it takes a few minutes. Register at the UK Plug-in Solar Registration website (myplugin.solar), using your name, postcode and your kit’s make and model. Save the on-screen confirmation, because you won’t get an email (EST checklist). Rules checked: . More in the rules.

Self-consumption

Self-consumption is the share of your panels’ output that you use at home as it’s made. It’s the part that cuts your bill. Whatever you don’t use flows to the grid, usually unpaid. The government’s examples for an 800 W kit assume a household at home all day uses 62% to 72% of the output, depending on how the panels face (DESNZ impact assessment). For homes that are empty for part or all of the day, our calculator uses 45–60% (in and out) and 30–45% (out all day); those two bands are our own assumptions. Running appliances in the daytime raises your share.

SEG (Smart Export Guarantee)

The Smart Export Guarantee is the scheme for being paid for electricity you send to the grid from an eligible home installation. Don’t count on being paid for electricity you export. The SEG needs an MCS-certified installation, which plug-in kits normally don’t have. Spare power simply flows to the grid unpaid unless your supplier offers something else (DESNZ impact assessment). A few suppliers offer export payments to plug-in users on their own terms, so ask your supplier before you buy. Rules checked: . See are plug-in solar panels worth it?

Socket circuit and spur

A socket circuit feeds your ordinary wall sockets. It’s often a ring that loops round several rooms. A spur is a branch off a circuit, sometimes feeding one fixed appliance such as a cooker or boiler. Plug the kit into an ordinary wall socket on a socket circuit, not a lighting circuit or a spur to a cooker or boiler. Never use an extension lead, multi-plug adaptor, RCD adaptor or travel adaptor (DESNZ product spec v2). If you’re not sure which circuit a socket is on, ask a qualified electrician. Rules checked: .

VA (volt-ampere)

VA measures “apparent power”: voltage multiplied by current, before allowing for how well the current and voltage line up (the power factor). For a solar inverter it’s usually very close to the watt figure. The law caps a plug-in kit’s AC output at 800 watts. The product spec also caps it at 800 VA and 3.5 A, so the current stays within limits even at low mains voltage (DESNZ product spec v2). Rules checked: .


Northern Ireland: the August 2026 change does not yet let you use plug-in solar there. It would need a separate change to Northern Ireland’s own electricity safety regulations, which is a decision for the NI Executive. We’ll update this when that happens (DESNZ impact assessment).

Spotted a term we should add, or a definition that’s unclear? Tell us. See how we research for how we check our wording.

Who wrote this

Wattleigh Editorial Team

The Wattleigh Editorial Team researches and writes every guide on this site. We work from official sources (legislation.gov.uk, DESNZ, Ofgem, the Energy Networks Association, Electrical Safety First) and show the date we last checked the rules on each page. Our guides are researched, not hands-on tested.

How we research and check the rules