Does plug-in solar work in winter and on cloudy days?
Yes, but far less. October–March output for an 800 W kit, why an upright panel beats a tilted one in December, and what winter output is worth.
Estimate what a plug-in solar kit could generate and save in your UK home, as a range, with every assumption shown. Nothing you type is stored.
How we're paid: We don't earn from any retailer on this page yet. If that changes, this line will say so. How we make money
With the inputs below: about 750 to 880 kWh a year, £90 to £140 a year, payback 3.6 to 5.6 years. See the workings
About 750 to 880 kWh a year from the kit
£90 to £140 a year
off your electricity bills, at 26.32p per kWh
Payback: 3.6 to 5.6 years at £500 kit cost
Your panels (800 W) are within your inverter's 800 W rating, so we expect little or no loss from the inverter limit.
Compare with the government's example: about £70 to £110 a year. DESNZ impact assessment (July 2026): an 800 W kit, an average GB household using 3,323 kWh a year and at home all day, average UK sunshine, no shading, no battery and no export payment. About £110 a year for a kit facing south at 30° (690 kWh maximum output, 62% used at home) and about £70 for an upright east/west kit (378 kWh, 72% used at home), valued at the 1 July to 30 September 2026 price cap.
Bars show an average year (2005–2023). A single month can be well above or below this.
| Month | kWh (average year) |
|---|---|
| January | 33 |
| February | 43 |
| March | 69 |
| April | 92 |
| May | 96 |
| June | 98 |
| July | 99 |
| August | 88 |
| September | 76 |
| October | 55 |
| November | 39 |
| December | 29 |
Real results vary with weather, shading and how much you use during the day. This is an estimate, not a guarantee.
Rules checked 2 November 2026.
An 800 W kit (800 W of panels, 800 W inverter), no shade, a household that is in and out (45%–60% used at home, our assumption), 26.32p per kWh, no export payment and a £500 kit. Same method as the calculator.
| Step | Angled frame (35°) | Upright (90°) |
|---|---|---|
| PVGIS yield per kWp, average year | 1,018.8 kWh | 742.9 kWh |
| × 0.8 kWp of panels | 815 kWh | 594 kWh |
| Range over the years (± 2 standard deviations) | 750 to 880 kWh | 540 to 650 kWh |
| Used at home (45%–60%) | 340 to 530 kWh | 240 to 390 kWh |
| × 26.32p = saving a year | £90 to £140 | £65 to £105 |
| Payback on £500 | 3.6 to 5.6 years | 4.9 to 7.9 years |
Scroll sideways to see the whole table.
Solar yield. We use the European Commission's Joint Research Centre tool PVGIS (version 5.3), with satellite weather data for 2005 to 2023 and its standard 14% allowance for cable, inverter and other system losses. For each of 8 places (London, Birmingham, Manchester, Newcastle, Glasgow, Cardiff, Plymouth, Aberdeen), 6 directions and 3 angles, PVGIS gives the average output per kWp of panels for each month. We multiply that by the size of your panels. For a kit split east and west, we average the east and west figures. Download the yield data (CSV): kWh per kWp, by place, direction, angle and month, retrieved 2026-10-10.
Ranges, not one number. PVGIS also gives how much the yearly total varies. We use the average plus or minus 2 standard deviations, which covers roughly 19 years in 20. Shading is applied as a band: "Some" takes off 10% to 25%, "Heavy" 30% to 50%. Those bands are our assumption, not measurements.
The 800 W limit. A legal kit's inverter can feed at most 800 W into your home's wiring. If your panels are rated above your inverter, some output on the sunniest hours is lost ("clipping"). Our data is monthly, so we can only approximate this. We assume the sunniest hours reach the panels' full rating and that every day is clear, which overstates the loss. Treat our clipping figure as an upper estimate. If your panels are rated at or below the inverter, we apply no loss.
Savings. Only electricity you use while the panels are generating cuts your bill. We multiply that share by your unit rate, and the rest by your export rate (zero by default). "Home most of the day" uses 62% to 72%, based on the government's impact assessment. "In and out" (45% to 60%) and "Out all day" (30% to 45%) are our own assumptions until we find an official figure. The default unit rate is the Ofgem price cap, 1 October to 31 December 2026, GB average, Direct Debit (no VAT on electricity until 31 March 2027).
Payback. Kit price divided by the yearly saving, as a range. It leaves out interest, future price changes and repairs. The government's assessment assumes around 10 years before at least the inverter may need replacing. If the slower end of your payback range is over 10 years, the calculator says so.
The yield figures for a south-facing kit at 35° fit the official examples. PVGIS gives about 815 kWh a year for an 800 W kit in central London, against the government's 690 kWh for average UK sunshine and the Energy Saving Trust's 700 kWh for Manchester. Our full method is on the how we research page.
Rule changes are recorded in our rules log. More on what plug-in solar saves is in our savings guides.
Yes, but far less. October–March output for an 800 W kit, why an upright panel beats a tilted one in December, and what winter output is worth.
UK plug-in solar kit prices with seller and date, the extras sellers leave out, VAT, and what each kit costs per unit of electricity you actually use.
Worked examples for three UK homes at the current Ofgem cap: yearly savings ranges, payback, and when a plug-in solar kit is not worth it.