Skip to content
Wattleigh

Does plug-in solar work in winter and on cloudy days?

Yes, but far less. October–March output for an 800 W kit, why an upright panel beats a tilted one in December, and what winter output is worth.

ResearchedRules checked See the rules

By Wattleigh Editorial Team · Last updated

How we're paid: We don't earn from any retailer on this page yet. If that changes, this line will say so. How we make money

Quick answer

Do solar panels work in winter in the UK? Yes, but they make far less. A south-facing 800 W plug-in kit tilted at 35° makes about 30% as much in December as in June in London, and about 18% as much in Glasgow. In London that’s roughly 29 kWh in December against 98 kWh in June. Cloud cuts output but doesn’t stop it.

Based on: EU JRC PVGIS v5.3 data (retrieved 10 October 2026) and Ofgem's price cap for October to December 2026

Prices: Ofgem price cap, 1 October–31 December 2026 · Data: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, retrieved 10 October 2026 · Evidence: researched. We have not tested kits ourselves. Every figure here is Wattleigh modelling for an unshaded spot, not a measurement or a promise.

In midwinter, panels hung upright do better than tilted ones because the sun is so low. From November to February, a south-facing kit in London makes roughly 140–160 kWh. At today’s price cap that’s worth up to about £38–£41, and only if you use every unit at home (dataset; Ofgem price cap).

New to plug-in solar? Start with the complete guide, or see all our savings guides.

The short answer: December against June

A kit with 800 Wp of panels, facing south, no shade:

City South, 35° tilt: December South, 35° tilt: June South, vertical: December South, vertical: June
London 29 kWh 98 kWh 35 kWh 50 kWh
Manchester 23 kWh 89 kWh 28 kWh 47 kWh
Glasgow 16 kWh 88 kWh 20 kWh 49 kWh

Wattleigh modelling: PVGIS output per kWp × 0.8, no shading, no 800 W inverter clipping. Source: our PVGIS dataset (CSV); method.

Per day, that’s about 0.9 kWh in December for a 35° kit in London and about 0.5 kWh in Glasgow. An upright kit makes about 1.1 kWh a day in London and about 0.6 kWh in Glasgow. (A kWh is the unit on your bill.)

Month by month, October to March

Average kWh per month for 800 Wp of panels facing south, no shade (Wattleigh modelling with PVGIS data):

October to March output in London: 800 Wp facing south, tilted 35° against vertical Bar chart of average kWh per month in London for 800 Wp of panels facing south, no shade. Tilted 35°: October 55, November 39, December 29, January 33, February 43, March 69. Vertical: October 51, November 42, December 35, January 37, February 42, March 57. November to February total: 143 kWh at 35° and 156 kWh vertical. The vertical panel makes more from November to January; in February the two are close. October to March: London, south London, 800 Wp of panels facing south, noshade. Average kWh per month.Tilted 35° (frame or stand)Vertical (upright, e.g. a railing)kWh0204060805551Oct3942Nov2935Dec3337Jan4342Feb6957MarShaded columns: November to FebruaryNovember to February total: 143 kWh tilted at35°, 156 kWh vertical.The upright panel makes more from November toJanuary. In February the two are close.Wattleigh modelling of EU JRC PVGIS data · wattleigh.com
Wattleigh modelling: average kWh per month in London for 800 Wp of panels facing south, no shade, tilted 35° and vertical. PVGIS output per kWp × 0.8, before 800 W inverter clipping. The November–February totals are worked out from unrounded values. Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, retrieved 10 October 2026; our PVGIS dataset (CSV).
Month London 35° London vertical Manchester 35° Manchester vertical Glasgow 35° Glasgow vertical
Oct 55 51 45 42 42 40
Nov 39 42 30 34 27 31
Dec 29 35 23 28 16 20
Jan 33 37 22 24 19 23
Feb 43 42 36 36 32 34
Mar 69 57 62 52 58 49
Nov–Feb total 143 156 110 121 94 107

Source: our PVGIS dataset (CSV). Totals are worked out from unrounded values, so they may differ by 1 kWh from the sum of the rounded months. For the full year, all eight cities and every direction, see how much electricity plug-in solar generates.

How we got these: EU JRC PVGIS v5.3, PVGIS-SARAH3 weather data for 2005–2023, 14% system losses, free-standing panels, city-centre locations, retrieved 10 October 2026. PVGIS gives output per 1 kWp of panels, and we multiplied by 0.8. The figures are averages over 19 years, so a single December can come in above or below them (method).

Clipping: these tables show output before clipping at the 800 W inverter limit, so for kits above 800 Wp they are upper bounds. Panels rarely get near their full rating in winter, so we’d expect clipping to matter little in these months. That’s our reasoning, not a measured result.

Why winter output is so low

Three things work against you from November to February:

  • Short days. There are fewer hours of daylight for the panels to work with.
  • A low sun. Its light passes through more of the atmosphere before it reaches you, so it’s weaker, and it strikes a tilted panel at a glancing angle.
  • More dull days. Thick, grey cloud is common in a British winter.

Cloud reduces output; it doesn’t switch it off. Panels still make some electricity from daylight on overcast days, just much less than in direct sun.

Our monthly figures already include cloudy days. PVGIS-SARAH3 is built from satellite records of the real weather from 2005 to 2023, not from clear-sky days only (EU JRC, Using PVGIS 5).

Why a vertical panel can win in winter

This matters if your kit will hang on a balcony railing. In our data, a panel standing upright and facing south makes more in December than the same panel tilted at 35°, in all eight cities. It also wins in November and January in all eight.

In February the two are close: within 2% in London, Birmingham, Manchester, Cardiff and Plymouth, with the upright panel 4–9% ahead in Newcastle, Glasgow and Aberdeen.

December output for 800 Wp of panels facing south, no shade:

City Nearly flat (15°) Tilted (35°) Vertical (90°) Vertical vs 35°
Plymouth 20.6 kWh 28.9 kWh 33.4 kWh +16%
London 20.1 kWh 29.0 kWh 34.6 kWh +19%
Cardiff 18.0 kWh 25.8 kWh 30.5 kWh +18%
Birmingham 18.0 kWh 26.5 kWh 32.2 kWh +21%
Manchester 15.1 kWh 22.6 kWh 27.6 kWh +22%
Newcastle 14.0 kWh 21.8 kWh 27.8 kWh +28%
Glasgow 10.0 kWh 15.5 kWh 19.7 kWh +27%
Aberdeen 10.2 kWh 16.9 kWh 22.7 kWh +35%

Wattleigh modelling: PVGIS December output per kWp × 0.8. Source: our PVGIS dataset (CSV).

Why: in midwinter the sun is low, so its light comes in at a shallow angle. An upright panel faces that light more squarely than a tilted one. The winter sun is lower the further north you go, and in our data the upright panel’s lead broadly grows too, from +16% in Plymouth to +27–35% in Newcastle, Glasgow and Aberdeen.

Why an upright panel catches more of the low December sun Two side views, not to scale, with both panels facing south. December: the sun stays low, so its light comes in at a shallow angle; an upright panel on a railing faces it more squarely, while a panel tilted at 35° gets the light at a glancing angle. June: the sun is high, so the tilted panel faces it more squarely and the upright panel gets glancing light. Over a whole year the tilted panel makes more; winter is when an upright south-facing panel holds up best. Low winter sun, high summer sun Side view, not to scale. Both panels facesouth, to the right.December: the sun stays lowTilted 35°UprightUpright panel: faces the low sun moresquarely.Tilted panel: the light strikes it at aglancing angle.June: the sun is highTilted 35°UprightTilted panel: faces the high sun moresquarely.Upright panel: the light strikes it at aglancing angle.Over a whole year the tilted panel makesmore. Winter is when an upright south-facingpanel holds up best.Original diagram by Wattleigh · wattleigh.com
Original diagram by Wattleigh, not to scale: why an upright panel catches more of the low December sun. The sun angles are drawn to show the idea only, with no measured values. The figures behind it are in the December table above (our PVGIS dataset).

The trade-off: the upright panel loses heavily in spring and summer, and over the whole year. In London, a vertical south-facing kit makes about 594 kWh a year against about 815 kWh at 35° (dataset).

So don’t choose vertical because of winter. But if a south-facing balcony railing is the spot you have, and you’re allowed to use it, winter is when it holds up best. Our balcony solar guide covers which balconies are allowed and how railing kits are fixed.

East, west and north-facing in winter

Upright panels facing other directions, 800 Wp, no shade:

City South vertical (Dec / Jan) East vertical (Dec / Jan) West vertical (Dec / Jan) North vertical (Dec / Jan)
London 34.6 / 36.9 kWh 8.2 / 10.5 kWh 9.1 / 10.3 kWh 2.4 / 3.1 kWh
Manchester 27.6 / 24.3 kWh 6.7 / 7.7 kWh 6.6 / 6.7 kWh 1.8 / 2.4 kWh
Glasgow 19.7 / 22.7 kWh 3.9 / 6.2 kWh 4.2 / 5.4 kWh 1.1 / 1.8 kWh

Wattleigh modelling: PVGIS output per kWp × 0.8. Source: our PVGIS dataset (CSV).

To be honest about it:

  • East or west: in December an upright east- or west-facing kit makes roughly a quarter of what a south-facing one does in London, and about a fifth in Glasgow. In London, that’s about 50 kWh in total from November to February.
  • North: a north-facing upright kit makes almost nothing from November to February: about 15 kWh across all four months in London and about 9 kWh in Glasgow.

Winter is when the gap between south and the other directions is widest. In summer, east and west close much of it (see the full direction tables).

Shade is worse in winter

A low sun throws long shadows. A neighbouring building, a tree, a wall or the balcony above you can shade your panels for much more of the day in December than in June. All our tables assume no shade at all, so a partly shaded spot will make noticeably less in winter than anything shown here.

The plug-in solar calculator has a “Shade on the panels” option. Its “Some” (10–25% loss) and “Heavy” (30–50% loss) bands are our own assumptions and apply across the whole year, so a spot that is shaded only in winter is hard to capture.

If your panels sit in shadow for most of a winter day, expect very little from them until spring.

What winter output is worth

You only save money on the electricity you use at home while the panels are generating. That share is called self-consumption.

Our rate: we use Ofgem’s price cap for 1 October to 31 December 2026: 26.32p per kWh for electricity (GB average, Direct Debit, no VAT on electricity until 31 March 2027). Your own tariff may differ (Ofgem price cap).

January and February fall under the next cap, which hadn’t been set when we checked, so we’ve valued them at the same 26.32p (our assumption). We’ll update this page when the new cap starts on 1 January 2027.

Worked example (London, south, 35°):

  1. PVGIS output per kWp, November to February: 48.2 + 36.3 + 40.7 + 53.2 = 178.4 kWh.
  2. × 0.8 kWp of panels = about 143 kWh.
  3. Used at home, if people are in and out (45–60%, our assumption) = about 64–86 kWh.
  4. × £0.2632 = about £17–£23 for the four winter months.

Wattleigh calculation from our PVGIS dataset (CSV).

Value of November–February output, 800 Wp, no shade, at 26.32p per kWh:

Set-up Nov–Feb output Out all day (30–45%) In and out (45–60%) Home most of the day (62–72%) Every unit used (ceiling)
London, south 35° 143 kWh £11–£17 £17–£23 £23–£27 £38
London, south vertical 156 kWh £12–£19 £19–£25 £25–£30 £41
Manchester, south 35° 110 kWh £9–£13 £13–£17 £18–£21 £29
Manchester, south vertical 121 kWh £10–£14 £14–£19 £20–£23 £32
Glasgow, south 35° 94 kWh £7–£11 £11–£15 £15–£18 £25
Glasgow, south vertical 107 kWh £8–£13 £13–£17 £17–£20 £28

The “Home most of the day” band comes from the government’s example, which assumes a household at home all day uses 62% of a 30° south-facing kit’s output and 72% of a vertical east/west kit’s output over a year (DESNZ impact assessment, Table 7). The other two bands are our own assumptions, the same ones our calculator uses.

Why winter may sit at the higher end (our reasoning): a winter kit makes a small amount of power, often under 1 kWh a day. A home’s background use (fridge, freezer, router, devices on standby) and daytime lighting or cooking may soak up much of that as it’s made.

So a larger share of winter output may be used at home than over a whole year. We haven’t measured this, and the calculator uses year-round bands.

Spare power: don’t count on being paid for electricity you export. The Smart Export Guarantee needs an MCS-certified installation, which plug-in kits normally don’t have. Spare power simply flows to the grid unpaid unless your supplier offers something else (DESNZ impact assessment, paras 32 and 61).

Snow, ice and wind

  • Snow or ice covering the panels stops most or all output until it slides off or melts. Leave it to clear by itself.
  • Never climb onto a roof, stand on a chair or ladder on a balcony, lean out of a window or reach over a railing to clear snow, ice or leaves from panels. A few kWh of winter output is never worth a fall. For cleaning, follow your kit maker’s instructions, which the product spec requires to cover safe cleaning (DESNZ product spec v2, 8.3.2).
  • Wind: don’t adjust, move or take down the mount in high wind. The government’s product spec describes a plug-in solar kit as panels, inverter, plug lead and a mounting system, with the maker showing by structural analysis that the mount is safe, including for wind and snow. It doesn’t allow mounts that rely only on cable ties, rope, string, adhesive tape, bungee cords or straps (product spec v2, 1 and 5.5.1). We only recommend kits that come with the manufacturer’s own mounting system, fitted as its instructions say. Those instructions must also give the kit’s wind and snow limits and how to fasten it or weigh it down (product spec v2, 8.3.2).
  • After a storm, look over the fixings, cables and connectors from somewhere you can stand safely. That’s our own good-practice advice: the product spec doesn’t mention storms, but it does ask makers to tell you to make routine visual checks of these parts (product spec v2, 8.3.2). If a panel or bracket has come loose, keep people away from underneath it and don’t try to refit it in the wind. If anything looks damaged, don’t touch the damaged part. Follow the kit’s instructions, and get a qualified electrician to check it if you’re unsure.

More on safe set-up: is plug-in solar safe?

Should you buy now or wait for spring?

The numbers, not a sales pitch:

Set-up Share of the year’s output made November–February
London, south 35° about 17.5%
London, south vertical about 26%
Manchester, south 35° about 15%
Manchester, south vertical about 23%
Glasgow, south 35° about 14%
Glasgow, south vertical about 21%

Wattleigh calculation: November–February output ÷ yearly output, per kWp. Source: our PVGIS dataset (CSV).

What that means:

  • Buying in autumn means your first four months are the weakest of the year. A 35° kit in London makes about 82% of its yearly output between March and October.
  • Over several years, the start date matters little. On average a kit makes about the same each year, whenever you buy it. Buying now mainly means a slow first winter with the full spring and summer ahead.
  • We don’t predict kit prices or energy prices. Compare current prices when you’re ready, and see are plug-in solar panels worth it? for payback ranges.
  • Before you switch on, whenever you buy: register your kit before you start using it: install it, register it, then switch it on. Use the UK Plug-in Solar Registration website (myplugin.solar). The official guidance says registering is a legal requirement (Energy Saving Trust checklist; Electricity North West). Step by step: how to register your plug-in solar kit.

No battery to save summer power for winter

Batteries are not part of the new rules. Plug-in batteries, and plug-in solar kits with a built-in or add-on battery, are not covered and must not be connected under this route (product spec v2, section 1). The government says it will keep looking at batteries, and we’ll update this page if that changes. More: can you add a battery to plug-in solar?

Who these winter figures won’t fit

  • Shaded spots. If a building, tree or the balcony above shades your panels in winter, expect noticeably less than anything here.
  • North-facing balconies. Expect almost nothing from November to February (see above).
  • Kits with more than 800 Wp of panels. Our figures are before clipping, so treat them as upper bounds.
  • Anyone hoping to store summer power. Batteries aren’t allowed under the plug-in route.
  • Northern Ireland. The August 2026 change does not yet let you use plug-in solar there, which is why it isn’t in our tables. It would need a separate change to Northern Ireland’s own electricity safety regulations, which is a decision for the NI Executive. We’ll update this when that happens (DESNZ impact assessment, para 12).

Next step


Rules checked: . Evidence: researched (modelled from public data, not measured by us).

Common questions

Do plug-in solar panels work on cloudy days?
Yes, but they make much less than in sun. Our monthly figures already include cloudy days, because they're averages of real weather from 2005 to 2023.
How much does an 800 W kit make in December?
With 800 Wp of panels facing south and no shade: about 29 kWh (tilted at 35°) to 35 kWh (vertical) in London, and about 16–20 kWh in Glasgow. That's roughly 0.5–1.1 kWh a day.
Is a vertical balcony panel better in winter?
Facing south, yes, from November to January. In December it beat a 35° panel in all eight cities in our data, by 16–35%. Over the whole year it makes less (about 594 against 815 kWh in London).
Does snow stop plug-in solar?
Snow or ice covering the panels stops most or all output until it clears. Let it melt or slide off by itself. Never climb onto a roof, stand on a chair or ladder on a balcony, lean out of a window or reach over a railing to clear snow, ice or leaves from panels.
Is it worth buying plug-in solar in winter?
The first months will be slow: a 35° south-facing kit makes only about 14–17.5% of its year's output from November to February in our Glasgow and London data. Over the life of the kit, when you buy matters little. In London, winter output is worth roughly £11–£30 over the four months at today's cap, depending on set-up and how much you use at home, with about £41 as the ceiling if you used every unit.
Can I store summer power for winter?
No. Plug-in batteries, and kits with a built-in or add-on battery, are not covered by the new rules and must not be connected under this route.

Keep reading

Everything in Savings

Who wrote this

Wattleigh Editorial Team

The Wattleigh Editorial Team researches and writes every guide on this site. We work from official sources (legislation.gov.uk, DESNZ, Ofgem, the Energy Networks Association, Electrical Safety First) and show the date we last checked the rules on each page. Our guides are researched, not hands-on tested.

How we research and check the rules