Skip to content
Wattleigh

Plug-in solar calculator: yield, savings and payback

Estimate what a plug-in solar kit could generate and save in your UK home, as a range, with every assumption shown. Nothing you type is stored.

EstimateRules checked See the rules

How we're paid: We don't earn from any retailer on this page yet. If that changes, this line will say so. How we make money

Savings estimate

Estimate, not a guarantee

With the inputs below: about 750 to 880 kWh a year, £90 to £140 a year, payback 3.6 to 5.6 years. See the workings

Where the panels go

England, Wales and Scotland. Pick the closest city.

Facing north-east or north-west? Choose North for a cautious figure, or East or West for a hopeful one.

Angle from flat ground. Most railing kits are upright or angled.

Shade on the panels

"Some" and "Heavy" losses are our assumption, not measured. Trees, walls or a balcony above you count.

Your kit

Total of all panels, 100 to 2,000 W. On the box as "Wp".

What the inverter can feed into your sockets. Legal kits: 800 W at most.

Default £500: middle of the government's "around £400 to £600".

Your electricity

Default: Ofgem price cap, 1 October to 31 December 2026, GB average, Direct Debit (no VAT on electricity until 31 March 2027). Use the rate on your bill if you know it.

When are you at home in the day?

Share of the output you use yourself. "Home most of the day" is based on the government's impact assessment (62–72%). The other two bands are our assumption, not official figures.

Only if you know it, for example from a smart meter. Replaces the band above.

Only if your supplier pays you for export. Don't count on being paid for electricity you export. The Smart Export Guarantee needs an MCS-certified installation, which plug-in kits normally don't have.

What you type stays in your browser. We don't send or store it.

About 750 to 880 kWh a year from the kit

£90 to £140 a year

off your electricity bills, at 26.32p per kWh

Payback: 3.6 to 5.6 years at £500 kit cost

Your panels (800 W) are within your inverter's 800 W rating, so we expect little or no loss from the inverter limit.

Compare with the government's example: about £70 to £110 a year. DESNZ impact assessment (July 2026): an 800 W kit, an average GB household using 3,323 kWh a year and at home all day, average UK sunshine, no shading, no battery and no export payment. About £110 a year for a kit facing south at 30° (690 kWh maximum output, 62% used at home) and about £70 for an upright east/west kit (378 kWh, 72% used at home), valued at the 1 July to 30 September 2026 price cap.

Month by month

Estimated output each month in an average year, London, facing southAverage year. Highest in July, about 99 kWh. Lowest in December, about 29 kWh. The table below gives every month.0255075100JFMAMJJASONDkWh

Bars show an average year (2005–2023). A single month can be well above or below this.

Monthly figures as a table
Estimated output by month, average year
MonthkWh (average year)
January33
February43
March69
April92
May96
June98
July99
August88
September76
October55
November39
December29

How we worked it out

  1. PVGIS average for London, facing south, 35°: 1,018.8 kWh per kWp a year.
  2. Your panels: 0.8 kWp × 1,018.8 = 815 kWh in an average year, before limits.
  3. Inverter limit (800 W): no loss, because the panels don't exceed it.
  4. Weather from year to year: × 0.92 to × 1.08 (PVGIS average ± 2 standard deviations).
  5. Shading: × 1.
  6. Output: 750 to 880 kWh a year (rounded to 10 kWh).
  7. Used at home: 45% to 60% (in and out: our assumption, not an official figure) = 340 to 530 kWh.
  8. Value: used kWh × 26.32p, plus exported kWh × 0p = £90 to £140 a year (rounded to £5).
  9. Payback: £500 ÷ the yearly saving (best case first) = 3.6 to 5.6 years. No interest, price changes or repairs included.

Assumptions

  • Solar yield: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, retrieved 2026-10-10. Panels on an open frame (PVGIS "free-standing"); panels flat against a wall run warmer and may produce a little less.
  • Place: nearest of our 8 places, London (city centre). Facing south; Angled frame (35°).
  • Shading: none (no loss applied).
  • Inverter limit: your panels don't exceed the 800 W rating, so no loss is applied.
  • Share used at home: 45% to 60% (in and out: our assumption, not an official figure).
  • Unit rate: 26.32p per kWh (Ofgem price cap, 1 October to 31 December 2026, GB average, Direct Debit (no VAT on electricity until 31 March 2027)).
  • No export payment assumed. Don't count on being paid for electricity you export. The Smart Export Guarantee needs an MCS-certified installation, which plug-in kits normally don't have.
  • Kit price: £500.
  • No battery: batteries are not covered by the plug-in solar rules.

Real results vary with weather, shading and how much you use during the day. This is an estimate, not a guarantee.

Rules checked 2 November 2026.

Northern Ireland: the August 2026 change does not yet let you use plug-in solar there. It would need a separate change to Northern Ireland's own electricity safety regulations, which is a decision for the NI Executive.

Batteries: Batteries are not part of the new rules. Plug-in batteries, and plug-in solar kits with a built-in or add-on battery, are not covered and must not be connected under this route.

Worked example: a south-facing flat in London

An 800 W kit (800 W of panels, 800 W inverter), no shade, a household that is in and out (45%–60% used at home, our assumption), 26.32p per kWh, no export payment and a £500 kit. Same method as the calculator.

Worked example for a south-facing London flat, two mountings
StepAngled frame (35°)Upright (90°)
PVGIS yield per kWp, average year1,018.8 kWh742.9 kWh
× 0.8 kWp of panels815 kWh594 kWh
Range over the years (± 2 standard deviations)750 to 880 kWh540 to 650 kWh
Used at home (45%–60%)340 to 530 kWh240 to 390 kWh
× 26.32p = saving a year£90 to £140£65 to £105
Payback on £5003.6 to 5.6 years4.9 to 7.9 years

Scroll sideways to see the whole table.

Source: EU JRC PVGIS v5.3 (PVGIS-SARAH3, 2005–2023), 14% system losses, retrieved 2026-10-10. Unit rate: Ofgem price cap, 1 October to 31 December 2026, GB average, Direct Debit (no VAT on electricity until 31 March 2027). Rules checked 2 November 2026.

How this calculator works

Solar yield. We use the European Commission's Joint Research Centre tool PVGIS (version 5.3), with satellite weather data for 2005 to 2023 and its standard 14% allowance for cable, inverter and other system losses. For each of 8 places (London, Birmingham, Manchester, Newcastle, Glasgow, Cardiff, Plymouth, Aberdeen), 6 directions and 3 angles, PVGIS gives the average output per kWp of panels for each month. We multiply that by the size of your panels. For a kit split east and west, we average the east and west figures. Download the yield data (CSV): kWh per kWp, by place, direction, angle and month, retrieved 2026-10-10.

Ranges, not one number. PVGIS also gives how much the yearly total varies. We use the average plus or minus 2 standard deviations, which covers roughly 19 years in 20. Shading is applied as a band: "Some" takes off 10% to 25%, "Heavy" 30% to 50%. Those bands are our assumption, not measurements.

The 800 W limit. A legal kit's inverter can feed at most 800 W into your home's wiring. If your panels are rated above your inverter, some output on the sunniest hours is lost ("clipping"). Our data is monthly, so we can only approximate this. We assume the sunniest hours reach the panels' full rating and that every day is clear, which overstates the loss. Treat our clipping figure as an upper estimate. If your panels are rated at or below the inverter, we apply no loss.

Savings. Only electricity you use while the panels are generating cuts your bill. We multiply that share by your unit rate, and the rest by your export rate (zero by default). "Home most of the day" uses 62% to 72%, based on the government's impact assessment. "In and out" (45% to 60%) and "Out all day" (30% to 45%) are our own assumptions until we find an official figure. The default unit rate is the Ofgem price cap, 1 October to 31 December 2026, GB average, Direct Debit (no VAT on electricity until 31 March 2027).

Payback. Kit price divided by the yearly saving, as a range. It leaves out interest, future price changes and repairs. The government's assessment assumes around 10 years before at least the inverter may need replacing. If the slower end of your payback range is over 10 years, the calculator says so.

The yield figures for a south-facing kit at 35° fit the official examples. PVGIS gives about 815 kWh a year for an 800 W kit in central London, against the government's 690 kWh for average UK sunshine and the Energy Saving Trust's 700 kWh for Manchester. Our full method is on the how we research page.

What it can't tell you

  • Exactly how much shade falls on your panels. A balcony above you, a tree or the next building can cut output a lot, especially in winter when the sun is low.
  • Your tariff. Time-of-use and fixed tariffs differ from the price cap. Use the unit rate on your bill.
  • Your own pattern of use. Running the washing machine or dishwasher in the middle of a sunny day raises the share you use; being out all week lowers it.
  • Short peaks. Clipping happens minute by minute, and our method only approximates it from monthly averages.
  • Whether your home and kit are suitable. That depends on the rules, your wiring and permission from your landlord or freeholder. Start with the rules.

Rule changes are recorded in our rules log. More on what plug-in solar saves is in our savings guides.

Guides that use these figures

Questions about the calculator

Why is my result a range?
Because no one can promise a single figure. Sunshine changes from year to year, shading is hard to judge, and the share of the output you use at home depends on your routine. The low end combines a dull year, the heavier end of your shading band and the lower share used at home. The high end combines a bright year, the lighter end of the shading band and the higher share.
Why does the 800 W limit matter if I have 890 W of panels?
Kits can include up to 2,000 W of panels (up to four panels), but the inverter still limits what reaches your sockets to 800 W. Panels rarely reach their full rating in the UK, so on most days 890 W of panels never hit the limit. On bright, cool middays they can, and the extra is lost. Our cautious estimate is a loss of up to about 3.0% a year for 890 W of panels on an 800 W inverter. The real loss is probably smaller.
Why does the calculator assume £0 for export?
Don't count on being paid for electricity you export. The Smart Export Guarantee needs an MCS-certified installation, which plug-in kits normally don't have. A few suppliers offer export payments to plug-in users on their own terms, so ask your supplier before you buy. If you already have an export rate, type it in.
Does facing east or west still work?
Yes, with less output. In London, panels angled at 35° and split east and west produce about 79% of what the same panels would facing south. Output is spread across the morning and evening, which can suit you if you are home then: the government's example assumes a household at home all day uses 72% of an upright east/west kit's output, against 62% for a south-facing one.
Is this a guarantee?
No. It is an estimate based on long-term weather data and the assumptions listed with every result. Your real output and savings will differ.

Keep reading